DVP type lashing eye is tested at 100% magnaflux and at 20.000 fatigue cycles. Additionally, it has a safety coefficient 4. For asymetric loads remember that the capasity has to be reduced as shown in the reference table. The bracket must always be aligned to the pulling direction (tolerance allowed +/-10). In particular applications the capasity which has to be used must be determined by the pulling inclination angle following this formula: Lc= C/b∙cosδ, where Lc stands for capasity needed per single bracket, c for load to lift, b for number of sling arms and δ for pulling inclination angle.
Images of the products are symbolic.
The table presents lashing eyes type DVC, their dimensions and other technical characteristics.
Size |
Working load limit t |
A mm |
B mm |
C mm |
D mm |
E mm |
F mm |
G mm |
H mm |
Weight kg |
Article No. |
M6 |
4 |
14 |
65 |
48 |
29 |
134 |
14 |
60 |
79 |
0,73 |
464501 |
M8 |
6,7 |
20 |
83 |
60 |
39 |
169 |
16 |
88 |
103 |
1,80 |
464502 |
M10 |
10 |
22 |
96 |
65 |
48 |
196 |
19,5 |
98 |
118 |
3,00 |
464503 |
M12 |
16 |
31 |
126 |
90 |
55 |
264 |
29 |
127 |
155 |
5,75 |
464504 |
M16 |
30 |
42 |
175 |
10 |
79 |
371 |
45 |
157 |
217 |
16,00 |
464505 |
Pictograms |
||||||||
Size |
0° |
0° |
90° |
90° |
0° - 45° |
45° - 60° |
0° - 45° |
45° - 60° |
Working load limit (t) |
||||||||
M6 |
4 |
8 |
4 |
8 |
5,6 |
4 |
8,4 |
6 |
M8 |
6,7 |
13,4 |
6,7 |
13,4 |
9,38 |
6,7 |
14,1 |
10,1 |
M10 |
10 |
20 |
10 |
20 |
14 |
10 |
21 |
15 |
M12 |
16 |
32 |
16 |
32 |
22,4 |
16 |
33,6 |
24 |
M16 |
30 |
60 |
30 |
60 |
42 |
30 |
63 |
45 |